Specifications |
Number of Channels |
4 |
2 Ohms |
1,500 W |
4 Ohms |
1,500 W |
8 Ohms |
1,250 W |
4 Ohms (br) |
3,000 W |
8 Ohms (br) |
3,000 W |
Output Power (V) |
70 V, 100 V Output, All Channels Driven
70 V (per channel): 1,500 W
100 V (per channel): 1,250 W |
Power Draw |
Sleep Mode: < 1 W
Standby Mode: 40 W
Idle (no signal): 55 W |
Current |
120 VAC Mains (Divide by 2 for 240 V)
Sleep Mode: 0.1 A
Standby Mode: 0.70 A
Idle (no signal): 1.00 A
All Channels Driven (Divide
by 2 for 240 VAC)
Typical: 8.0 A
|
Dissipation |
Thermal (All Channels Driven)
Sleep Mode: 3.4 BTU/hr
Standby Mode: 136 BTU/hr
Idle (no signal): 187 BTU/hr
Typical (1/8 maximum power): 850 BTU/hr |
Voltage Gain
|
Selectable at 26 dB, 32 dB, 38 dB, or 1.4
V |
Damping Factor
|
>250 (8 Ohm load <1 kHz) |
High-Pass Filter |
Input: 80 Hz 2nd order |
Distortion |
SMPTE (typical): <0.5%
THD-N (typical): <0.5% (8 Ohm, 10 dB below rated power,20
Hz to 20 kHz) |
Channel Separation |
-75 dB (dB from full output, 1 kHz) |
Signal to Noise Ratio |
20 Hz to 20 kHz (unweighted): >111 dB
|
Frequency Response |
20 Hz to 20 kHz, +/-0.05 dB |
Input Connector |
Balanced: Euroblock 3.5 mm, 1/4" TRS
and XLR Combo jack |
Input Impedance |
10 kOhm |
Maximum Input Level |
+21 dBu |
Output Connector |
Speaker: Neutrik speakON |
Connection |
Data: Euroblock 3.5 mm - Gnd, 18 V, In, Out
|
Level Control |
Remote DC: Euroblock 3.5 mm - Gnd, CV, V+
per input |
Attenuation |
Per Channel: Front panel, software, offset
link group, and remote. Fully off = Mute |
Protection |
Amplifier: Inrush current limitation, temperature
monitoring, output over-power protection, mains fuses |
Cooling |
Continuously variable temperature controlled
axial fan(s) |
Environmental |
32 to 113°F (0 to 45°C) non condensing
|
Dimensions (W x H x D) |
19.0 x 3.5 x 16.8" (482.6 x 88.9 x 426.7
mm) |
Weight |
< 28.0 lb (12.7 kg) |